РЕФЕРАТИВНА БАЗА ДАНИХ "УКРАЇНІКА НАУКОВА"
Abstract database «Ukrainica Scientific»


Бази даних


Реферативна база даних - результати пошуку


Вид пошуку
Пошуковий запит: (<.>ID=REF-0000716206<.>)
Загальна кількість знайдених документів : 1

Очеретнюк А. О. 
Ультраструктурні зміни респіраторного відділу легень щурів при застосуванні колоїдно-гіперосмолярних розчинів / А. О. Очеретнюк, Б. О. Кондрацький, О. В. Паламарчук, В. В. Ковальчук, Я. Б. Кондрацький // Експерим. та клініч. фізіологія і біохімія. - 2019. - № 2. - С. 31-39. - Бібліогр.: 19 назв. - укp.

In this experimental research the influence of a HAES-LX-5 % colloid-hyperosmolar solution and the reference preparation of a protein-salt solution Lactoprotein with sorbitol (LPS) and the control solution of 0,9 % NaCl was studied on the functional state of the lungs according to the ultrastructural indices of ratsі lungs on cellular and subcellular levels. The solutions were used in the dose of 10 ml/kg intravenous per day during 168 hours. The stereometric analysis of the lung tissue showed that in rats that were injected with solutions of 0,9 % NaCl, HAES-LX-5 % and LPS, there were no significant differences in the relative volume of damaged lung areas as compared to the ones of intact animals. During the experiment, this indicator varied from 0,071 to 0,111 cm<^>3/cm<^>3 (p >> 0,05). From the first to the thirtieth day of the experiment the relative volume of the damaged areas of the lungs was significantly less (p << 0,001) in all groups of the experimental animals. The changes in the morphological structure of the lungs of animals that were injected with infusion solutions were studied on the 7<^>th, 14<^>th and 30<^>th days from the start of the experiment. The results of the study assessing the ultrastructure of rats' lungs, the bronchial, vascular and alveoli conducting systems suggest that the administration of HAES-LX-5 % solution to animals does not cause pathological changes in the lungs ultrastructure: in the bronchial and vascular conducting systems, alveoli, air-blood barrier, alveolarocytes of II type and unlike the reference preparation, does not increase the adhesion of leukocytes to endotheliocytes and does not increase the number of alveolar macrophages, confirming its harmlessness and the absence of potential allergenic properties. Conclusions: the study confirmed the safety of these three solutions, the absence of their toxic effects on the structures of the rats' lungs during the entire observation period (from the first day to the thirtieth one). The obtained results can be added to the pharmacological characteristics of the colloidal hyperosmolar preparation of HAES-LX-5 % and the protein-salt hyperosmolar solution of LPS.


Індекс рубрикатора НБУВ: Е60*733.23 + Р251.72

Рубрики:

Шифр НБУВ: Ж16160 Пошук видання у каталогах НБУВ 
Додаткова інформація про автора(ів) публікації:
(cписок формується автоматично, до списку можуть бути включені персоналії з подібними іменами або однофамільці)
  Якщо, ви не знайшли інформацію про автора(ів) публікації, маєте бажання виправити або відобразити більш докладну інформацію про науковців України запрошуємо заповнити "Анкету науковця"
 
Національна бібліотека України імені В. І. Вернадського
Відділ наукового формування національних реферативних ресурсів
Інститут проблем реєстрації інформації НАН України

Всі права захищені © Національна бібліотека України імені В. І. Вернадського