РЕФЕРАТИВНА БАЗА ДАНИХ "УКРАЇНІКА НАУКОВА"
Abstract database «Ukrainica Scientific»


Бази даних


Реферативна база даних - результати пошуку


Вид пошуку
Пошуковий запит: (<.>ID=REF-0000754073<.>)
Загальна кількість знайдених документів : 1

Kupriyanov O. 
The influence of measurement error on the risks of the consumer and the manufacturer when completing connections / O. Kupriyanov // Ukr. j. of mech. eng. and materials science. - 2020. - 6, № 1. - С. 22-29. - Бібліогр.: 9 назв. - англ.

The influence of the measuring device error on the consumer's and manufacturer's risks was studied for three cases of the organization of completing: complete interchangeability, selective completing and completing with ranking. The presence of measurement error does not allow to avoid risks; however, their values must be estimated so that they do not have a significant impact on manufactured products. The study was carried out for a "shaft-hole" connection by statistical modeling, the laws of dimension distribution were accepted as normal, as well as the laws of distribution of measurement errors. For the case of completing with complete interchangeability, the accuracy of two-stage control was studied; it is recommended to establish the accuracy of the initial measurements at 20 - 25 % of the tolerance field, repeated measurements at 10 - 12 % of the tolerance field, while the manufacturer's risk does not exceed 0,2 %, the consumer's risk is practically zero. In the case of selective completing, the requirements for the accuracy of the measuring device are significantly higher than in the case of completing with complete interchangeability, since errors are possible not only at the limits of the tolerance field but also at the limits of the selection groups. Therefore, the measurement error should not exceed 5 % of the tolerance field width; it is also advisable to limit the number of selection groups. When completing with ranking, the accuracy of the measuring device has the least impact on risks, especially if the number of parts in the batch is large enough and the measurement error complies with the standards in mechanical engineering. It was established that for the number of sets greater than 10, almost complete assemblability is achieved and the risks associated with the measurement error become insignificant. Thus, if it is necessary to increase the accuracy of products at the assembly stage, it is recommended to use completing with ranking instead of selective completing.


Індекс рубрикатора НБУВ: Ж104 + У010.357.3

Рубрики:

Шифр НБУВ: Ж44086 Пошук видання у каталогах НБУВ 
Повний текст  Наукова періодика України 
  Якщо, ви не знайшли інформацію про автора(ів) публікації, маєте бажання виправити або відобразити більш докладну інформацію про науковців України запрошуємо заповнити "Анкету науковця"
 
Національна бібліотека України імені В. І. Вернадського
Відділ наукового формування національних реферативних ресурсів
Інститут проблем реєстрації інформації НАН України