Velychko O. 
Calibration of high and ultra-high frequency power meters in the range of up to 30 MHz / O. Velychko, S. Kursin, V. Gaman // Вимірюв. техніка та метрологія : міжвід. наук.-техн. зб.. - 2022. - Вип. 83 (ч. 4). - С. 36-42. - Бібліогр.: 17 назв. - англ.

High-frequency (HF) and ultra-high-frequency (UHF) power measurements are applied in various industries both in the development and design of radio-electronic equipment and in testing, commissioning, or repair. Since such measurements are one of the basic types of measurement for metrological support in the field of radio engineering and communication, it is necessary to ensure metrological traceability of the calibration of working standards and measuring instruments to standards on fundamental constants in wide frequency and dynamic ranges. The National primary standard of Ukraine for units of power of electromagnetic oscillations in coaxial paths reproduces units of power in the frequency range 0,03 - 18 GHz, and the frequency range of the nomenclature of watt-meters and power converters are much wider - from 9 kHz, and for some types of converters even from direct current. The calibration and measurement capabilities of HF and UHF power measurement of national laboratories of different countries were studied for the possibility of solving the issue of expanding the frequency range of calibration of HF and UHF power meters. The analysis of data on the calibration factor and the efficiency factor in coaxial paths with a resistance of 50 Ohm in the Database of Key Comparisons of the International Bureau of Weights and Measures was carried out. A study of possible solutions was carried out and a scheme was developed to reproduce a unit of power by units of voltage and resistance using a precision voltmeter Boonton 9242 RF for the calibration of measuring transducers Rohde'Schwarz NRP-Z55 and NRP6A in the frequency range from 0,1 - 30 MHz. A reproduction model was created based on the developed scheme, and the contributions of the reproduction model components to the calibration result and the corresponding uncertainties of the model components were estimated. The measurement uncertainty budget was drawn up based on the proposed calibration model of radio signal power measuring transducers.



Шифр НБУВ: Ж70321 Пошук видання у каталогах НБУВ 
Повний текст  Наукова періодика України 
Додаткова інформація про автора(ів) публікації:
(cписок формується автоматично, до списку можуть бути включені персоналії з подібними іменами або однофамільці)
  Якщо, ви не знайшли інформацію про автора(ів) публікації, маєте бажання виправити або відобразити більш докладну інформацію про науковців України запрошуємо заповнити "Анкету науковця"
 
Національна бібліотека України імені В. І. Вернадського
Відділ наукового формування національних реферативних ресурсів
Інститут проблем реєстрації інформації НАН України

Всі права захищені © Національна бібліотека України імені В. І. Вернадського